GD 50

Wall Lining System

GD 50 system drawing

A wall lining system installed on a metal frame over walls of brick, pumice block, aerated concrete and similar. It is built with direct fixing brackets and DU and DC profiles. A single layer of Aypan board is screwed to the Aypan DC profiles.

Performance

A wall lining system installed on a metal frame over walls of brick, pumice block, aerated concrete and similar. It is built with direct fixing brackets and DU and DC profiles. A single layer of Aypan board is screwed to the Aypan DC profiles.

  • Can be used to achieve a true, even surface on walls that are out of level and out of plumb.
  • Its mechanical strength is greater than that of GD30. It can therefore be installed on taller walls.
  • Can be used where the thermal and sound insulation of the existing wall needs to be improved.
  • The system is lightweight and adds little load to the building. It minimises loss of life and property under seismic loads.
  • Also used to conceal and enclose services that run in front of or along the surface of the wall.
  • Also used in repair and refurbishment work.
  • The average weight of the system is 15-17 kg/m².
  • Together with the existing wall, the sound insulation of the system is 55-73 dB.
  • The lining can be installed with a distance of up to 120 mm between the existing wall and the face of the Aypan board.
  • Direct fixing brackets must be fixed to the TC profiles at maximum 125 cm centres.
  • The cavity between the profiles can be used for service runs.
  • Optionally, stone wool insulation boards can also be placed between the profiles.
  • Quick, easy and economical to install.

Specification

In accordance with the project drawings and details,

  1. Fix Aypan DU profiles, made from galvanised steel sheet complying with TS EN 14195, to the floor and ceiling at 60 cm centres using Aypan screws and plastic wall plugs.
  2. Cut the Aypan DC profiles to length.
  3. Before fixing, apply 50 mm Aypan acoustic sealing tape to the back of the DU profiles and the direct fixing brackets.
  4. Prepare support pieces by cutting them from profile, and fix them to the existing wall with screws and plastic wall plugs at 60 cm centres horizontally and at maximum 125 cm centres vertically.
  5. Fit the DC 50 profiles into the DU 50 profiles at 60 cm centres and fix them to the wall with the support pieces.
  6. Fix the 12.5 mm Aypan boards to the DU 50 and DC 50 profiles with 25 mm Aypan plasterboard screws.
  7. Where necessary, cut the Aypan boards to size.
  8. Pre-fill gaps wider than 3 mm with Aygips jointing compound.
  9. Apply Aygips joint tape over the Aypan board joints.
  10. Finish the wall lining by applying Aygips jointing compound over the joint tape.

Price per m², including all materials and wastage, loading on site, horizontal and vertical transport, unloading, contractor’s profit and overheads.

Consumption Table

Material quantities required for 1 m². Tap a product name to open its product page.

Product CodeMaterial40 cm**60 cm**Unit
AL125BY250Aypan (12.5 mm)1.001.00m²
AK50NDC300Aypan DC50 Profile2.802.00m
AK50NDU300Aypan DU50 Profile0.800.80m
BN050YB025Aypan Acoustic Sealing Tape1.301.30m
AB030AG120Aypan Direct Fixing Bracket2.201.50pcs
AB042MB000Aypan Wafer-Head Screw4.203.00pcs
AB048DV145Aypan Screw and Plastic Wall Plug Set2.202.20pcs
AB035BV025Aypan Sharp-Point Screw 3.5x25 mm19.0015.00pcs
BN050DB090Aypan Joint Tape1.401.40m
AG001DD025Aygips Plasterboard Jointing Compound0.400.40kg
Stone Wool1.001.00m²
AG001ST025Aygips Satin Finishing Plaster1 for every 1 mm of thicknesskg
AK022DP270Aypan Perforated Corner BeadAs per projectm

Materials for One Door

Material
Door Support Profile
L Bracket Nut and Bolt Set
Steel Anchor
  • *Wastage not included.
  • **DC profile spacing
  • ***For DU and DC profiles in other sizes, contact our technical department.
  • ***Calculated for a 4x2.5 m wall.