GD 30

Wall Lining System

GD 30 system drawing

A wall lining system installed on a metal frame over walls of brick, pumice block, aerated concrete and similar. It is built with direct fixing brackets and TU and TC profiles. A single layer of Aypan board is screwed to the Aypan TC profiles.

Performance

A wall lining system installed on a metal frame over walls of brick, pumice block, aerated concrete and similar. It is built with direct fixing brackets and TU and TC profiles. A single layer of Aypan board is screwed to the Aypan TC profiles.

  • Can be used to achieve a true, even surface on walls that are out of level and out of plumb.
  • Can be used where the thermal and sound insulation of the existing wall needs to be improved.
  • The system is lightweight and adds little load to the building. It minimises loss of life and property under seismic loads.
  • Also used to conceal and enclose services that run in front of or along the surface of the wall.
  • Also used in repair and refurbishment work.
  • The average weight of the system is 15 kg/m².
  • Together with the existing wall, the sound insulation of the system is 53-71 dB.
  • The lining can be installed with a distance of up to 120 mm between the existing wall and the face of the Aypan board.
  • Direct fixing brackets must be fixed to the TC profiles at maximum 125 cm centres.
  • The cavity between the profiles can be used for service runs.
  • Optionally, stone wool insulation boards can also be placed between the profiles.
  • Quick, easy and economical to install.

Specification

In accordance with the project drawings and details,

  1. Fix Aypan TU profiles, made from galvanised steel sheet complying with TS EN 14195, to the floor and ceiling at 60 cm centres using Aypan screws and plastic wall plugs.
  2. Cut the TC 60 profiles to length.
  3. Before fixing, apply 50 mm Aypan acoustic sealing tape to the back of the TU profiles and the direct fixing brackets.
  4. Fix Aypan direct fixing brackets to the existing wall with Aypan screws and plastic wall plugs at 60 cm centres horizontally and at maximum 125 cm centres vertically.
  5. Bend the legs of the Aypan direct fixing brackets to suit the position of the wall lining.
  6. Place the TC 60 profiles between the two legs of the Aypan direct fixing brackets and fit them into the TU 28 profiles.
  7. Fix the Aypan direct fixing brackets to both flanges of the TC 60 profiles with Aypan bracket screws.
  8. Fix the 12.5 mm Aypan boards to the TU 28 and TC 60 profiles with 25 mm Aypan plasterboard screws.
  9. Where necessary, cut the Aypan boards to size.
  10. Pre-fill gaps wider than 3 mm with Aygips jointing compound.
  11. Apply joint tape over the Aypan board joints.
  12. Finish the wall lining by applying Aygips jointing compound over the joint tape.

Price per m², including all materials and wastage, loading on site, horizontal and vertical transport, unloading, contractor’s profit and overheads.

    Consumption Table

    Material quantities required for 1 m². Tap a product name to open its product page.

    Product CodeMaterial40 cm**60 cm**Unit
    AL125BY250Aypan (12.5 mm)1.001.00m²
    AK60ETC300Aypan TC 60 Profile2.802.00m
    AK30ETU300Aypan TU 28 Profile0.800.80m
    BN050YB025Aypan Acoustic Sealing Tape1.301.30m
    AB030AG120Aypan Direct Fixing Bracket2.201.50pcs
    AB042MB000Aypan Wafer-Head Screw1.301.30pcs
    AB048DV145Aypan Screw and Plastic Wall Plug Set2.202.20pcs
    AB035BV025Aypan Sharp-Point Screw 3.5x25 mm19.0015.00pcs
    BN050DB090Aypan Joint Tape1.401.40m
    AG001DD025Aygips Plasterboard Jointing Compound0.400.40kg
    Stone Wool1.001.00m²
    AG001ST025Aygips Satin Finishing Plaster1 for every 1 mm of thicknesskg
    AK022DP270Aypan Perforated Corner BeadAs per projectm

    Materials for One Door

    Material
    Door Support Profile
    L Bracket Nut and Bolt Set
    Steel Anchor
    • *Wastage not included.
    • **TC profile spacing
    • ***Calculated for a 4x2.5 m wall.