ALAT 10
Suspended Ceiling System

A suspended ceiling system for use where the void between the slab and the ceiling is no more than 20 cm. It is formed by screwing a single layer of plasterboard to a one-way grid made of direct fixing brackets and galvanised steel sheet.
System Data Sheet and Documents
Performance
A suspended ceiling system for use where the void between the slab and the ceiling is no more than 20 cm. It is formed by screwing a single layer of plasterboard to a one-way grid made of direct fixing brackets and galvanised steel sheet.
- Can be used in all types of building, such as offices, hospitals, hotels and housing.
- This system can be chosen to conceal services in the ceiling, where the sound insulation, thermal insulation and fire resistance of the room need to be improved, or to give the ceiling a decorative appearance.
- The void between the suspended ceiling and the existing slab is 10-20 cm.
- The average weight of the system is 16 to 18 kg/m².
- The sound insulation of the system is 46-73 dB. It varies with the properties of the existing slab.
- To EN 4102, the fire resistance of the system can be F 30 or F 60 with Aypan® Red.
- To improve sound and fire performance, suitable mineral wool must be laid.
- Quick, easy and economical to install.
Specification
In accordance with the project drawings and details,
- Fix Aypan TU profiles, made from galvanised steel sheet complying with TS EN 14195, to the existing walls at 60 cm centres using screws and plastic wall plugs.
- Mark the line of the first primary profile on the ceiling, 10 cm from the existing wall.
- Mark the subsequent lines at maximum 60 cm centres.
- Fix Aypan direct fixing brackets along the marked lines at maximum 100 cm centres with steel anchors.
- Bend the bracket legs to suit the ceiling void depth.
- Cut the Aypan TC profiles to length.
- Place the TC profiles between the two legs of the brackets.
- Fix the brackets to both flanges of the TC profiles with bracket screws.
- Use profile connectors at the joints of the TC profiles.
- Fix the Aypan boards to the TU and TC profiles with 25 mm plasterboard screws.
- Where necessary, cut the boards to size.
- Pre-fill gaps wider than 3 mm with Aygips jointing compound.
- Cover the screw heads with jointing compound.
- Apply joint tape over the board joints.
- Finish the suspended ceiling by applying jointing compound over the joint tape.
Price per m², including all materials and wastage, loading on site, horizontal and vertical transport, unloading, contractor’s profit and overheads.
Consumption Table
Material quantities required for 1 m². Tap a product name to open its product page.
| Product Code | Material | 40 cm** | 50 cm** | 60 cm** | Unit |
|---|---|---|---|---|---|
| AL125BY250 | Aypan (12.5 mm) | 1.00 | 1.00 | 1.00 | m² |
| AK60ETC300 | Aypan TC 60 Profile | 2.60 | 2.00 | 1.80 | m |
| AK30ETU300 | Aypan TU 28 Profile | 0.80 | 0.80 | 0.80 | m |
| AB090EP000 | Aypan Profile Connector | 0.52 | 0.40 | 0.36 | pcs |
| AB048DV145 | Aypan Screw and Plastic Wall Plug Set | 1.50 | 1.50 | 1.50 | pcs |
| AB006CD045 | Aypan Steel Anchor | 2.60 | 2.00 | 1.80 | pcs |
| AB035BV025 | Aypan Sharp-Point Screw | 18.00 | 15.00 | 14.00 | pcs |
| AB030AG120 | Aypan Direct Fixing Bracket | 2.60 | 2.00 | 1.80 | pcs |
| AB42MB000 | Aypan Wafer-Head Screw | 5.20 | 4.00 | 3.60 | pcs |
| BN050DB090 | Aypan Joint Tape | 1.40 | 1.40 | 1.40 | m |
| AG001DD025 | Aygips Plasterboard Jointing Compound | 0.40 | 0.40 | 0.40 | kg |
| AG001ST025 | Aygips Satin Finishing Plaster | 1 for every 1 mm of thickness | kg | ||
| AK022DP270 | Aypan Perforated Corner Bead | As per project | m | ||
- *Wastage not included.
- **Secondary profile spacing
- ***Calculated for an area of 5x5 m.