2 TP 22
Partition Wall System

A non-load-bearing partition wall system. Two layers of Aypan board are screwed to each face of a double metal frame (Aypan DC) made from galvanised steel sheet.
System Data Sheet and Documents
Performance
A non-load-bearing partition wall system. Two layers of Aypan board are screwed to each face of a double metal frame (Aypan DC) made from galvanised steel sheet.
- Can be used in all types of building, such as offices, hospitals, hotels and housing, where higher sound insulation and fire resistance than 1TP22 are required and wider services must run through the wall.
- Can be installed up to a maximum height of 6.50 m.
- The average weight of the system is 56-60 kg/m².
- The fire resistance is F 60 with Aypan® White and F90 with Aypan® Red.
- Insulation boards such as stone wool can be placed between the profiles to improve the sound and thermal insulation of the system. In the high sound insulation configuration, the sound insulation is 60-63 dB.
- Where the profiles meet the slab and the walls, Aypan Acoustic Sealing Tape must be applied to the back of the profiles to prevent sound bridges.
- The cavity between the profiles can be used for service runs.
Specification
In accordance with the project drawings and details,
- Fix two rows of Aypan DU profiles (galvanised steel sheet complying with TS EN 14195), leaving a gap between them, to the floor and ceiling at 60 cm centres using Aypan screws and plastic wall plugs.
- Apply Aypan acoustic sealing tape to the back of the Aypan DC profiles (made to TS EN 1495) that are to be fixed to the DU profiles and side walls.
- Size the DC profiles to suit the wall height (cutting them if necessary).
- Fit the DC profiles into both lines of DU profiles at 40 or 60 cm centres to form a double frame.
- If required, place stone wool boards of suitable thickness and density between the DC profiles.
- Cut the Aypan boards to size and fix them to the profiles with plasterboard screws: 25 mm for the first layer and 35 mm for the second.
- Repeat the same procedure on the other face of the wall.
- Pre-fill gaps wider than 3 mm with Aygips jointing compound.
- Cover the screw heads with Aygips jointing compound.
- Apply joint tape over the Aypan board joints.
- Finish the partition wall by applying Aygips jointing compound over the joint tape.
Price per m², including all materials and wastage, loading on site, horizontal and vertical transport, unloading, contractor’s profit and overheads.
Consumption Table
Material quantities required for 1 m². Tap a product name to open its product page.
| Product Code | Material | 40 cm** | 60 cm** | Unit |
|---|---|---|---|---|
| AL125BY250 | Aypan (12.5 mm) | 4.00 | 4.00 | m² |
| AK50NDC300 | Aypan DC50 Profile | 5.60 | 4.00 | m |
| AK50NDU300 | Aypan DU50 Profile | 1.60 | 1.60 | m |
| BN050YB025 | Aypan Acoustic Sealing Tape | 2.60 | 2.60 | m |
| AB048DV145 | Aypan Screw and Plastic Wall Plug Set | 4.40 | 4.40 | pcs |
| AB035BV025 | Aypan Sharp-Point Screw 3.5x25 mm | 38.00 | 30.00 | pcs |
| AB035BV035 | Aypan Sharp-Point Screw 3.5x35 mm | 38.00 | 30.00 | pcs |
| BN050DB090 | Aypan Joint Tape | 2.80 | 2.80 | m |
| AG001DD025 | Aygips Plasterboard Jointing Compound | 0.80 | 0.80 | kg |
| Stone Wool | 1.00 | 1.00 | m² | |
| AG001ST025 | Aygips Satin Finishing Plaster | 1 for every 1 mm of thickness | kg | |
| AK022DP270 | Aypan Perforated Corner Bead | As per project | m | |
Materials for One Door
| Material |
|---|
| Door Support Profile |
| L Bracket Nut and Bolt Set |
| Steel Anchor |
- *Wastage not included.
- **DC profile spacing
- ***For DU and DC profiles in other sizes, contact our technical department.
- ***Calculated for a 4x2.5 m wall.