According to the project and details,

· Aypan TU profiles made of galvanized steel sheet according to TS EN 14195 should be fixed to the base and ceiling by using Aypan screws and plastic dowels at 60 cm intervals.

· TC 60 profiles should be cut.

· Before fixing, 50 mm Aypan sound insulation tape should be adhered to the back of TU profiles and frames.

· Aypan agraffee should be fixed to the existing wall with Aypan screws and plastic dowels at maximum 60 cm intervals in vertical and 60 cm intervals in horizontal.

· The Aypan chafing wings should be adjusted by bending according to the wall position.

· TC 60 profiles should be placed between two wings of Aypan plates and inserted between TU 28 profiles. Aypan brackets should be fixed to both blades of TC 60 profiles with Aypan brackets.

· 12.5 mm Aypan should be fixed to TU 28 and TC 60 profiles with 25 mm Aypan self-tapping screws. If necessary, Aypan should be cut and sized.

· Pre-fill the gaps more than 3 mm with Aygips grouting plaster. Joint tape should be adhered to Aypan joints.

· The cladding wall should be formed by applying Aygips joint filler plaster on the joint tape.

The price is 1 m2 including all kinds of materials and losses, loading in the workplace, horizontal and vertical transport, unloading and contractor profit and general expenses.